 ==== Configuration Parameters ==== ==== Configuration Parameters ====
- 
  
 == AUTOTHRESHOLD_INTERFACE_DISCARDS == == AUTOTHRESHOLD_INTERFACE_DISCARDS ==
Line 6: Line 5:
 This field contains the number of discards per second beyond which the alarm is activated. When this field is 0 (zero) the autothreshold for interface discards is disabled globally. This field contains the number of discards per second beyond which the alarm is activated. When this field is 0 (zero) the autothreshold for interface discards is disabled globally.
  
 +
 +== AUTOTHRESHOLD_PROCESS_NUMBER ==
 +
 +This field contains the percentage of the number of processes over the maximum exceeded which is triggered an alarm.
  
 == AUTOTHRESHOLD_BGPPEER_STATUS == == AUTOTHRESHOLD_BGPPEER_STATUS ==
Line 16: Line 19:
 This field contains the string used as email subject when emails are sent for automatic threshold. The default value is //​**"​DEVICE %DEVICE_NAME% Threshold"​**//​. These special keywords are also available: This field contains the string used as email subject when emails are sent for automatic threshold. The default value is //​**"​DEVICE %DEVICE_NAME% Threshold"​**//​. These special keywords are also available:
   * **%DEVICE_NAME%**:​ the name of the device   * **%DEVICE_NAME%**:​ the name of the device
 +  * **%DEVICE_IPADDR%**:​ the IP address of the device
   * **%EVENT_DESCR%**:​ the event description   * **%EVENT_DESCR%**:​ the event description
   * **%EVENT_STATUS%**:​ the event status name   * **%EVENT_STATUS%**:​ the event status name
 +  * **%ELEMENT_TAGS%**:​ additional tags of the entity (or device if the threshold is related to a device)
  
  
Line 32: Line 37:
  
 When this field is 1 (true) will be raised an alarm when a server in a loadbalanced service ​ goes down. When this field is 1 (true) will be raised an alarm when a server in a loadbalanced service ​ goes down.
 +
 +== AUTOTHRESHOLD_OSPF_INTERFACE ==
 +
 +When this field is 1 (true) will be raised an alarm when an interface as the OSPF status Down or the status changes.
 +
 +== AUTOTHRESHOLD_OSPF_NEIGHBOR ==
 +
 +When this field is 1 (true) will be raised an alarm when an OSPF neighbor as a Down state or the state changes.
  
  
Line 38: Line 51:
 Maximum number of events in a the api alarmMultiget request. If this field is 0 all events will be released in a single response. Maximum number of events in a the api alarmMultiget request. If this field is 0 all events will be released in a single response.
  
 +
 +== THRESHOLD_EMAIL_SUBJECT ==
 +
 +This field contains the string used as email subject when emails are sent for custom threshold. The default value is //​**"​NeMo:​ Device %DEVICE_NAME% Threshold"​**//​. These special keywords are also available:
 +  * **%DEVICE_NAME%**:​ the name of the device
 +  * **%EVENT_DESCR%**:​ the event description
 +  * **%EVENT_STATUS%**:​ the event status name
 +  * **%ELEMENT_TAGS%**:​ additional tags of the entity
 +
 +
 +== THRESHOLD_EMAIL_DEBUG ==
 +
 +When this field is 1 (true) additional info are inserted in the custom email body.